ATEX · PLC · Modbus · SCADA
Control & automation glossary
Hazardous-area, PLC, industrial-network and SCADA terms, explained plainly with examples from the field.
Hazardous areas (ATEX/IECEx)
- ATEX
- The European directive setting requirements for equipment used in explosive atmospheres; the name comes from the French ATmosphères EXplosibles.
- IECEx
- The international certification scheme for equipment in explosive atmospheres, run by the IEC and based on the IEC 60079 series of standards.
- Equipment Protection Level (EPL)EPL
- The equipment protection level states how safe a device is as an ignition source, and maps directly to the zones where it may be used.
- Hazardous-area zones (Zone 0, 1, 2)
- Dividing a site by the likelihood of an explosive atmosphere: Zone 0 continuously or for long periods, Zone 1 likely in normal operation, Zone 2 rarely and briefly.
- Temperature class (T1 to T6)
- The highest temperature a device’s surface can reach; it must stay below the auto-ignition temperature of the gas on site.
- Gas groups (IIA, IIB, IIC)
- Gases classified by how easily they ignite and pass a flame: IIA least severe (propane), IIB (ethylene), IIC most severe (hydrogen, acetylene).
- Flameproof protection (Ex d)Ex d
- A protection concept that lets an explosion happen inside the enclosure, which withstands it and cools the escaping flame through its gaps so the surrounding atmosphere does not ignite.
- Intrinsic safety (Ex i)Ex i
- A protection concept that limits the electrical energy in a circuit so it cannot produce an igniting spark or heat, even under fault conditions.
PLC programming & control
- Programmable logic controller (PLC)PLC
- An industrial computer built to control machines and processes: it reads sensors and switches, runs the control program, and drives motors and valves, repeatedly and reliably.
- Structured Text (ST)ST
- A textual programming language in IEC 61131-3 resembling Pascal, used for complex PLC logic, calculations and state machines.
- PID controllerPID
- A control algorithm that computes its output from the difference between the setpoint (SP) and the measured value (PV), in three parts: proportional, integral and derivative.
- 4-20 mA signal4-20 mA
- The most widely used analogue signal in industrial measurement: 4 mA is the bottom of the range and 20 mA the top, and current, unlike voltage, is not affected by cable length.
- HART protocolHART
- A digital protocol carried on top of the 4-20 mA signal itself, allowing transmitter configuration, reading and diagnostics without interrupting the analogue measurement.
- IEC 61131-3
- The international standard that unified PLC programming: five languages, the data types, the program organization units and the standard function blocks.
- Ladder logic (LD)LD
- A graphical PLC language drawn like relay circuits: rails, contacts and coils. The most widely used language in maintenance.
- Scan cycleScan
- The loop a PLC repeats thousands of times a minute: read the inputs, run the program top to bottom, write the outputs.
- Process image
- A copy in controller memory of every input and output, refreshed once at the start and once at the end of each scan.
- Watchdog timerWatchdog
- A timer in the controller firmware that stops execution and raises a fault if one scan takes longer than allowed.
- Task
- The scheduling unit in a controller: which programs run, how often, and at what priority.
- Program organization unit (POU)POU
- The unit every piece of PLC code lives in. The standard defines three: PROGRAM, FUNCTION and FUNCTION_BLOCK.
- Function block (FB)FB
- A unit with inputs, outputs and internal memory that persists between scans, used by declaring an instance of it.
- Function (FUN)FUN
- A unit that takes inputs and returns one value with no memory at all: the same inputs always give the same result.
- PROGRAM
- The top program organization unit: bound to a task, executed cyclically, and keeping its variables between scans.
- Seal-in (latch)
- A pattern that keeps an output running after a momentary button press, by feeding the output back into its own start condition.
- Interlock
- A condition that prevents a device from starting, or stops it, to protect the process or people, whatever the operator wants.
- Permissive
- A condition that must be true before a device is allowed to start, but which does not stop it once it is running.
- On-delay timer (TON)TON
- A standard function block whose output Q becomes true after IN has stayed true for PT without interruption, and resets as soon as IN drops.
- Off-delay timer (TOF)TOF
- A block whose output Q stays true for PT after IN goes false, then drops.
- Rising edge detection (R_TRIG)R_TRIG
- A block whose output Q gives a one-scan pulse at the moment input CLK goes from false to true.
- One-shot
- Logic that performs an action once when an event happens, instead of every scan the condition stays true.
- SR and RS flip-flopsSR / RS
- Two standard blocks that hold a boolean state: SR is set-dominant, RS is reset-dominant.
- State machine
- A pattern where the process is in exactly one known state at a time and moves between states on defined conditions.
- CASE statementCASE
- A selection statement that runs one branch depending on an integer or enumerated value. It is what state machines in ST are built from.
- IF statementIF
- The conditional in ST: IF ... THEN ... ELSIF ... ELSE ... END_IF. The most used statement in the language.
- Boolean expression
- An expression whose result is TRUE or FALSE, built from comparisons and the operators AND, OR, XOR and NOT.
- Operator precedence
- The order an expression is evaluated in: brackets, then negation, then multiply and divide, then add and subtract, then comparisons, then AND, XOR and OR.
- Integer division
- Dividing two integers in ST gives an integer and the fraction is dropped, which is a common cause of an unexpected zero.
- Type conversion
- Explicit functions that move a value between types, such as INT_TO_REAL, REAL_TO_INT, TRUNC and TIME_TO_DINT.
- Data type
- The classification that fixes a variable size, value range and permitted operations: BOOL, INT, DINT, REAL, TIME and the rest.
- Retained variable (RETAIN)RETAIN
- A variable held in retentive memory, so it keeps its value through a power cut and restart.
- Analogue scaling
- Turning the raw count from an input card into an engineering unit an operator understands: metres, bar or degrees.
- NAMUR NE43NE43
- A recommendation defining current bands outside 4-20 mA that signal a sensor fault rather than a valid measurement.
- Step timeout
- A timer watching each step of a sequence: if the step does not finish in its expected time, raise a fault instead of waiting forever.
- Alarm deadband
- A gap between the value that raises an alarm and the value that clears it, so the alarm does not chatter around the trip point.
- ISA-18.2
- The alarm management standard for process industries: the alarm lifecycle from design to review, and the alarm rates considered acceptable.
- Anti-windup
- Handling that stops the integral term of a PID from growing without limit while the output is saturated at its high or low clamp.
- Siemens SCLSCL
- The Siemens name for Structured Text in TIA Portal and STEP 7: IEC 61131-3 compatible with its own conventions.
- CODESYS
- A vendor-independent IEC 61131-3 development environment, used as the base for many manufacturers including Beckhoff, WAGO and Schneider.
Industrial networks
- Modbus protocolModbus
- A simple, open industrial protocol dating from 1979: a client asks, servers answer from numbered registers. It runs over RS485 (RTU) or Ethernet (TCP).
- MQTT protocolMQTT
- A lightweight publish/subscribe messaging protocol through a broker, ideal for carrying sensor data from remote sites to a server.
SCADA & HMI
- SCADA
- Supervisory control and data acquisition: collects readings from distributed controllers and sensors, presents them to operators, and manages alarms, commands and history.
Industrial IoT
- Edge computing
- Processing data close to where it is produced, on site, instead of sending everything to the server: filtering, calculations and local decisions.